Back to fleet / Machine 61
2026-05-07 18:19:41
— M-61

Machine 61

Tapping · Bay C · Threading · Vencat HC-FL · 48 rpm
Streaming · 25.6 kHz · 3 ch
2026-05-07 18:19:41
!
— Recommendation
WATCH

Envelope spectrum shows energy at the outer-race fault frequency (BPFO). Damage is established but not yet severe.

— Action
Plan bearing replacement on the carriage assembly. Order parts now if not in stock.
— Window
Within the next 14–21 days.
— HEALTH OVER TIME
— HEALTH
LIVE
0
/ 100
WATCH
Drift detected — recommend inspection within 30 days
— FREQUENCY MATCH
  • Outer race bearing wear
    78
  • Rotating imbalance
    32
  • Shaft misalignment
    5
  • Inner race bearing wear
    4
  • Rolling element wear
    3
  • Bearing cage wear
    2
— UPTIME & DUTY CYCLE
Last 24 h
Uptime
0.0 h / day
0.0 of 24 h · 0.0% calendar
Duty cycle
0.0 %
Active head-time / total scheduled time
— TIME-DOMAIN WAVEFORM
LIVE
rpm 48
channel CRANK-RAD
rate 25.6 kHz
— Time/div
— Channel
X · Radial Y · Axial Z · Tangential
TIME (s)
— SPECTROGRAM
LIVE
rpm 48
channel CRANK-RAD
rate 25.6 kHz
— Time/div
— Channel
TIME (s) · FREQUENCY (Hz) on Y
— POWER SPECTRAL DENSITY
LIVE
rpm 48
channel CRANK-RAD
rate 25.6 kHz
— Channel
FREQUENCY (Hz)
— ENVELOPE SPECTRUM
LIVE
rpm 48
channel CRANK-RAD
rate 25.6 kHz
— Channel
FREQUENCY (Hz)
— X – Y PHASE-SPACE ORBIT
LIVE
rpm 48
channel CRANK-RAD
rate 25.6 kHz
→ X · RADIAL ↑ Y · AXIAL
X · Y AMPLITUDE
— TIME-DOMAIN STATS
LIVE
— RMS
0.0752 g
— KURTOSIS
4.15
— PEAK
0.423 g
— CREST FACTOR
5.36