— M-39
Machine 39
Streaming · 25.6 kHz · 3 ch
2026-05-07 18:18:58
— Recommendation
WATCH
1× rotational energy is climbing above the learned baseline — a classic signature of mass imbalance on the rotating assembly.
— Action
Check rotor for buildup, missing/loosened balance weights, or worn punch tooling.
— Window
Address within the next planned changeover (≈ 7–10 days).
— HEALTH OVER TIME
— HEALTH
0
/ 100
WATCH
Drift detected — recommend inspection within 30 days
— FREQUENCY MATCH
- ▢ Rotating imbalance 68
- ▢ Shaft misalignment 5
- ▢ Outer race bearing wear 4
- ▢ Inner race bearing wear 4
- ▢ Rolling element wear 3
- ▢ Bearing cage wear 2
— UPTIME & DUTY CYCLE
Last 24 hUptime
0.0 h / day
0.0 of 24 h · 0.0% calendar
Duty cycle
0.0 %
Active head-time / total scheduled time
— TIME-DOMAIN WAVEFORM
LIVE
— Time/div
— Channel
X · Radial Y · Axial Z · Tangential
TIME (s)
— SPECTROGRAM
LIVE
— Time/div
— Channel
TIME (s) · FREQUENCY (Hz) on Y
— POWER SPECTRAL DENSITY
LIVE
— Channel
FREQUENCY (Hz)
— ENVELOPE SPECTRUM
LIVE
— Channel
FREQUENCY (Hz)
— X – Y PHASE-SPACE ORBIT
LIVE
→ X · RADIAL ↑ Y · AXIAL
X · Y AMPLITUDE
— TIME-DOMAIN STATS
— RMS
0.0650 g
— KURTOSIS
2.94
— PEAK
0.265 g
— CREST FACTOR
4.20